DS-11090

Being one of the established names in the market our firm is indulged in providing OT Anesthesia Machines.

  • Precise construction
  • Reliability
  • Fine finish
  • Durable nature
  • Robustness
  • Optimum strength
  • Construction: Trolley made by tubular ringed steel section electrolytically powder coated or stainless steel
  • Suitable drawer for keeping anesthesia kit / accessories
  • Extended platform at rear for two 10 ltrs. (Water cap.) cylinders
  • Small roller bearings, antistatic castors, for easy mobility and brakes
  • Top tray provided at eye level for keeping monitoring equipments
  • Hook for breathing circuit
  • Wipe clean stainless steel top
  • Unitized rota meter block for oxygen & oxide with fine adjustment controls & color coated knob and luminous back plate. Oxygen flow meter calibrated from 100cc/min to 10 Itrs. Minute & Nitrons oxide flow meter from 200cc/min to 12 liters/min down Stream receipt of oxygen
  • One gold man type vaporizer for halothene
  • Non return cum blow off valve in circuit ensures that pressure does not build-up beyond 200cm. Water column & minimizes risk of back flow of gases.
  • 60 psi outlet for driving ventilator
  • Emergency Oxygen flush valve At table level to give 35-60 ltrs/min for emergencies
  • Cylinder yokes: Pin indexed yokes one each of oxygen & nitrous oxide
  • 50 mm diameter, color coded gauges fitted at convenient angle for better visibility & clarity
  • High efficiency regulators for reliability one each for 02 & N2o
  • One Mag gills or Brain circuit
DS-90A Anesthesia Machine

Due to the proficiency of our team in this dominion, we provide for our customers, Anesthesia Machine.

  • High tensile strength

  • Long working life

  • Anti-corrosive

  • Excellent finishing

  • Abrasion resistance

  • Construction: Trolley made by tubular rigid steel section electrolytically powder coated or stainless steel
  • Suitable drawer for keeping anesthesia kit
  • Extended platform at rear for one 10 ltrs. (Water capacity) cylinder
  • Small roller bearings, anti-static castors, for easy mobility and brakes
  • Top tray provided at eye level for keeping monitoring equipments
  • Hook for breathing circuit
  • Wipe clean stainless steel top
  • Unitised rota meter block for oxygen & nitrous oxide with fine adjustment controls & color coated knob and luminous back plate. Oxygen flow meter calibrated from 100cc/min to 10 Itrs. Minute & Nitrous oxide flow meter from 200cc/min to 12 liters/min down Stream receipt of oxygen
  • One gold man type vaporizer for halothane
  • Non return cum emergency oxygen unit with blow off valve in circuit ensures that pressure does not build-up beyond 200 cm .water column & minimize risk of back flow of gases. 46
  • Cylinder yokes: Pin indexed yokes one each of oxygen & nitrous oxide 50 mm diameter, color coded gauges fitted at convenient angle for better visibility & clarity
  • High efficiency regulators for reliability one each for 02 & N2o Self sealing valve attachment for additional oxygen source from central gas pipe line
  • One Maggill’s or Bain circuit
DS-90B Portable Anesthesia Machine

Understanding the changing demands of our respected customers, we are offering a wide gamut of Portable Anesthesia Machine 111.

  • Reliability

  • Long lasting

  • Easy to carry

  • Provides ultimate solution

  • Construction: trolley made by tubular rigid steel section electromagnetically powder coated or stainless steel
  • Suitable drawer
  • Unitised rotameter block for oxygen & nitrous oxide with fine adjustment controls & colour coated knob and luminous back plate
  • Oxygen flow meter calibrated from 100 cc/min to 10 Itrs. / Minute & Nitrous oxide flow meter from 200cc/min to 12 liters/min down Stream receipt of oxygen
  • One gold man type vaporizer for halothane
  • Non return cum emergency oxygen unit with blow off valve in circuit ensures that pressure does not build-up beyond 200 cm. water column & minimize risk of back flow of gases.
  • Two pre set regulators (forged quality) one each for 02 & N20 with high pressure tubing non inter changeable for connection with flow meter inlet
  • One Magill’s & bain circuit
DS-90C Anaesthesia Machine-Rewa

Construction: Steel electrostatically powder coated or stainless steel:
– Capacious drawer for keeping anaesthesia kit/accessories
– Extended platform at rear for two 10 ltrs. (Water Cap.) cylinders
– Large roller bearings, antistatic castors, for easy mobility and brakes
– Top tray provided at eye level for keeping monitoring equipments
– Hook for breathing circuit a Wipe clean stainless steel top
– Provision to fit ventilator .
– Convenient mounting of circle absorber (Opt.)

  • Capacious drawer for keeping anaesthesia kit/accessories
  • Extended platform at rear for two 10 ltrs. (Water Cap.) cylinders
  • Large roller bearings, antistatic castors, for easy mobility and brakes
  • Top tray provided at eye level for keeping monitoring equipments
  • Hook for breathing circuit a Wipe clean stainless steel top
  • Provision to fit ventilator .
  • Convenient mounting of circle absorber (Opt.)
  • Emergency drug tray fitted at convenient place
  • Unitised rota meter block for oxygen & nitrous oxide with fine adjustment controls & colour coated knob and luminous back plate. Oxygen flow meter calibrated from 100cc/min to 10 Itrs./ Minute & Nitrous oxide flow meter from 200cc/min to 12 liters/min down Stream receipt of oxygen & (air 0 to 12 Hrs. optional)
  • One plenum type vaporizer for ether (optional) & one gold man type vaporizer for halo thane, provision to mount three vaporizer at a time
  • Non return cum blow off valve in circuit ensures that pressure does not huld-up beyond 200cm. Water column & minimizes risk of back flow of gases a
  • 60 psl outlet for driving ventilator
  • Change over system open circuit or close circuit a Emergency Oxygen flush valve at table level to give 35-60 ltrs/min for emergencies
  • Cylinder yokes: Pin indexed yokes two each of oxygen & nitrous oxide
  • 63 mm diameter, color coded gauges fitted at convenient angle for better visibility & clarity, one gauge for 02 & one gauge for N20 shown the line pressure
  • High efficiency regulators for reliability two each for 02 & N20
  • One Mag gill’s or Bain circuit a
  • One B.P Apparatus. Dimension
DS-90D

Understanding the changing demands of our respected customers, we are offering a wide gamut of Portable Anesthesia Machine 111.

  • Reliability

  • Long lasting

  • Easy to carry

  • Provides ultimate solution

  • Construction: trolley made by tubular rigid steel section electromagnetically powder coated or stainless steel
  • Suitable drawer
  • Unitised rotameter block for oxygen & nitrous oxide with fine adjustment controls & colour coated knob and luminous back plate
  • Oxygen flow meter calibrated from 100 cc/min to 10 Itrs. / Minute & Nitrous oxide flow meter from 200cc/min to 12 liters/min down Stream receipt of oxygen
  • One gold man type vaporizer for halothane
  • Non return cum emergency oxygen unit with blow off valve in circuit ensures that pressure does not build-up beyond 200 cm. water column & minimize risk of back flow of gases.
  • Two pre set regulators (forged quality) one each for 02 & N20 with high pressure tubing non inter changeable for connection with flow meter inlet
  • One Magill’s & bain circuit